Document Reference: ABS Mounting Guide
Last Updated: 12 May, 2026
Ambulance Bay Scanner (ABS) Installation & Mounting Guide
Purpose
This guide provides mounting specifications and installation requirements for the Athena Security Ambulance Bay Scanner (ABS), including:
- Wall mounting points
- Floor mounting points
- L-bracket placement
- Mounting dimensions
- Hole specifications
- Recommended installation layout
1. System Mounting Overview
The ABS system uses:
- 6 wall mounting points
- 4 floor mounting points
Each wall mounting point requires an individual L-bracket.
Mounting Point Layout
Wall Mounting Points
- 3 mounting points on the left side
- 3 mounting points on the right side
Floor Mounting Points
- 2 mounting points on the left leg
- 2 mounting points on the right leg
2. Wall Mounting Instructions
Wall Mount Configuration
Each wall mounting location uses a dedicated steel L-bracket fastened to:
- The wall structure
- The ABS frame
Reference layout shown on Page 3 of the source document.
Wall Mount Heights
Measured from floor level to mounting point centerline:
| Mount Position | Height |
|---|---|
| Top Mount | 2135 mm |
| Middle Mount | 1835 mm |
| Lower Mount | 1535 mm |
Horizontal Spacing
Distance between left and right mounting brackets:
- 928 mm center-to-center
L-Bracket Specifications
Typical L-Bracket Dimensions
| Dimension | Measurement |
|---|---|
| Vertical Leg | 100 mm |
| Horizontal Leg | 100 mm |
| Thickness | 6 mm |
Wall Anchor Hole Specifications
| Specification | Measurement |
|---|---|
| Hole Diameter | Ø10 mm |
| Hole Depth | 75 mm |
Recommended Hardware
- Concrete anchors or lag bolts suitable for structural wall material
- Minimum embedment depth: 75 mm
3. Floor Mounting Instructions
Floor Mount Configuration
The ABS frame includes four floor mounting locations:
- 2 mounting points on left support leg
- 2 mounting points on right support leg
Reference layout shown on Page 4.
Floor Mount Spacing
Outside Distance
- 532.5 mm
Inside Distance
- 452.5 mm
Measurements are symmetrical from the center wall reference line.
Floor Anchor Specifications
| Specification | Measurement |
|---|---|
| Hole Diameter | Ø15 mm |
| Hole Height | 20 mm |
| Mount Offset from Wall | 14 mm |
| Anchor Depth | Lag bolt or anchor length + 20 mm |
4. Recommended Installation Procedure
Step 1 — Verify Installation Area
- Confirm wall and floor surfaces are structurally sound
- Verify adequate clearance around the scanner
- Ensure mounting surfaces are level
Step 2 — Mark Wall Mount Locations
Using the dimensions provided:
- Mark all 6 wall mounting locations
- Confirm:
- 928 mm center spacing
- Correct vertical elevations
Step 3 — Install L-Brackets
- Drill Ø10 mm holes to 75 mm depth
- Install anchors
- Secure each bracket independently
Step 4 — Position ABS Unit
- Align the scanner with wall brackets
- Attach frame to brackets
- Verify plumb and level alignment
Step 5 — Secure Floor Mounts
- Mark all 4 floor anchor locations
- Drill Ø15 mm mounting holes
- Install lag bolts or anchors
- Tighten all hardware to specification
Step 6 — Final Inspection
Verify:
- All hardware is tightened
- Scanner is level
- No frame movement exists
- All mounting points are secured
5. Important Notes
- All dimensions are in millimeters
- Each wall mounting point requires its own L-bracket
- Structural mounting surfaces are required
- Use installation hardware rated for the scanner weight and environmental conditions
Manufacturer Information
Athena Security
248 Addie Roy Road, Suite C101
Austin, TX 78746
www.athena-security.com